6. Slowly pull on the recoil starter handle, shown in Figure 6, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the
cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
7. If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting
again. If problems persist, call 1-866-460-9437, Monday - Friday, 8 AM - 4 PM Central Time.
8. Once the engine has started and runs for about a minute, move the choke lever approximately half way towards the “open” position. Wait an
additional 30 seconds and then move the choke lever completely over to the “open” position.
9. Allow this generator to run for several minutes before connecting any electrical devices.
Figure 4 - Fuel Valve in the “on” position Figure 5 - Choke Lever in the “closed” position. (Refer to the Generator
Components chart to find the location of the Choke Lever.)
Figure 6 - Pull-cord for starting the engine.
USING THE GENERATOR
After the engine has been running for several minutes, electrical devices may be connected to this generator.
AC Usage
Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this
ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator is 3,000 and 3,500, respectively.
Model AC-G0002 Rated (Running) Wattage 3000
Model AC-G0002 Surge Wattage 3500
The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis.
The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a
refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices
typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement.
Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator
15