3M 2210 Metal Detector User Manual


 
Off
On
Hz
TM
Dynatel
33 KHz
2210
Receiver Front Panel
577 Hz
Battery Test
Indicator
Battery
Level Mark
Gain Adjust Depth Freq
6 ‘C’ cells
6 ‘AA’
cells
3
Receiver Operation:
1. Press
to turn receiver on and see battery level. Hold down for continuous Battery
Test. If bar graph is to the left of the battery level mark, replace batteries. Note: when
batteries are low, the battery test indicator
remains on.
2. Press
to match Frequency to transmitter output or select for passive power
locating.
3. Press to set Gain when bar graph is not visible or is closed. For High Volume ( ),
hold down
while turning unit on. To return to normal volume, turn unit off, then on
again.
4. Make broad sweeps with receiver handle in line with target cable path to get maximum
bar graph closure; press
. Maximum bar graph and numeric indication occurs directly
over cable.
5. Place the receiver upright on the surface directly over cable. With handle parallel to
path, press
to display estimated Depth. Press again to display numeric Current
indication. Cable with highest current indication is the target. Press to return to trace
mode, and press
. Unit returns to trace mode automatically after eight seconds.
Note: Active Duct Probe (sonde) depth will differ from cable depth due to the shape of the
electromagnetic field of the ADP. Conversion tables are provided with the ADP to obtain
accurate depth estimates.
Battery Installation