Troy-Bilt 01919-1 Portable Generator User Manual


 
Troubleshooting
TROUBLESHOOTING
Problem
No
AC
output
is
available,
but engine
is
running.
When loads are
connected, engine runs
good but bogs down.
Engine shuts down during
operation.
Engine lacks power.
Cause
I. Circuit breaker is open.
2.
Poor connection or defective cord set.
3.
Connected device is bad.
4.
Fault in generator.
I.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Engine speed is too slow.
4.
Shorted generator circuit.
Out of gasoline.
Load is too high.
Solution
I. Reset circuit breaker.
2.
Check and repair.
3.
Connect another device that is in
good condition.
4.
Contact Authorized Service Facility.
I.
Disconnect shorted electrical load.
2.
See "Don't Overload Generator".
3.
Contact Authorized Service Facility.
4.
Contact Authorized Service Facility.
Fill fuel tank.
See "Don't Overload Generator".