Troy-Bilt 01919-1 Portable Generator User Manual


 
Section
4:
Operation
L
RECEPTACLES
overload the generator. See "Don't Overload
1201240 Volt AC,
30
Amp, Locking
Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250VoltAC loads at 30 Amps (or
Use each receptacle to operate 120Volt AC, single-phase,
greater) (Figure 5).You can use the same 4-wire cord if you
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
plan to run a I2OVolt load.
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20. Amps (or greater).
Cord Set
(Hot)
1
X
(Hot)
I
NEMA
L
14-30
Tf/
Ground (Green)
This receptacle powers I201240 Volt AC, 60
Hz,
single
phase loads requiring up to 5,550 watts of power
(5.55
kW) at 23.1 Amps for I2OVolts or 240Volts.The
outlet is protected by a push-to-reset circuit breaker.
120Volt AC, 20 Amp, Duplex
Receptacles
Each duplex receptacle (Figure 6) is protected against
overload by a push-to-reset circuit breaker.
GENERATOR ADAPTER
CORD SET
The getierator is equipped with a 25' generator adapter cord
set designed for a 240Volt, 30Amp grounded neutral circuit
(Figure 7).The generator adapter. cord set provides a
convenient supply of emergency power into your dwelling so
-
that your generator can be operated safely outside.
-
The maximum load on each outlet is 2OAmps.The
maximum total load on both yellow wire outlets
or
black
wire outlets is 30 Amps.
NOTE:
Follow all safety precautions when connecting any
extension cord or device to the generator.