Power Acoustik M-944 Spreader User Manual


 
6
OPERATION
WARNING
BEFORE OPERATING THE CONTROL PANEL - MAKE SURE THAT NO ONE IS INSIDE
THE HOPPER OR NEAR THE SPINNER.
1. Electric Throttle Control Panel Switch functions
(Sequence of Operations)
A. ON/OFF System power activated (ready to start). Spreader engine is not running.
Spreader conveyor is not engaged.
B. START (Engine only)
1 . On On switch depressed.
2. Choke (cold engine ) Hold down for 5 seconds to move the throttle actuator to the
choke position.
Note: Choking a warm engine may not be necessary
3. Start Hold down until engine starts.
4. LO / HI Decreases / increases engine speed - adjust as engine warms up. Lo will
stop the choke function.
C. TO ENGAGE Spreader Conveyor
1. Push CONV switch only after you are sure no one is in the hopper or near the spinner! This lights up
the red indicator light, if light does not light, take care to verify that the light is not malfunctioning.
!
ON
OFF
CHOKE
LO
HI
START
CONV.
MOUNTING
TABS
RED LENSE