Pentair Time Master Swimming Pool User Manual


 
LIMITED WARRANTY
Compool Corporation warrants tot he purchaser oft his control system, for the period of
one year from the date of original purchase for use, that any defective product proved to
be caused by faulty workmanship or faulty material, will be repaired or replaced at
Compool's option for no charge, providing the product is returned to Compool
with all transportation charges prepaid.
First Ninety
Days: During the first ninety days after installation, if any Compool control
shall be found to be defective due solely to faulty material and workmanship, Compool
Corporation will additionally cover the reasonable replacement cost charged by an
authorized service company.
After Ninety Days: Between the ninety-first day and the end of the first year after
installation, no allowances will be made for labor for the removal or reinstallation of any
soclaimed defective products
This warranty covers the Time Master Controller,
LX-10
Service Center, VOR-24
Valve Operators, and optional Remote Controls, including all components and parts.
It does not include Valves or Sensors. It extends to the first retail purchaser and any
subsequent owners of the system.
This limited warranty applies only to controls which have been installed and maintained
in strict accordance with installation and operating instructions provided by Compool
Corporation, using installation hardware supplied
and/or recommended in writing by
Compool, and to controls which have been connected to the correct supply voltage.
This limited warranty does not apply to any controls which have been repaired or
altered by anyone other than Compool ora person authorized by it;
orwhich have been
subject to misuse, neglect or accident; or which have been damaged by wind, freezing
or other cause, thing, person or act of God; or which have been subject to damage in
transit, during
installation,or by someone other than Compool Corporation; or which
have been damaged because of a defect in a component or part which is not part of the
Compool Control System; or upon which the serial number has been altered, effaced or
removed.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state. Compool
Corpora!ion does not authorize any person to create
any other obligation or liability in connection with Compool controls. Compool
Corporation makes no warranty of merchantability or fitness for
any use. Any implied
warranty applicable to Compool controls is limited in duration to the duration of this
written warranty.
Compool Corporation shall not be liable for consequential or incidental damages
resulting from breach of this written warranty or any implied warranty. Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of incidental or consequential damages may not apply to you.
To
exerclse this warranty, send defective unit, with copy of dated receipt,
postage prepaid, to:
COMPOOL CORPORATION
599 Fairchild
Drive, Mountain View, California 94043-221
7
MEMBER
599 Fairchild Drive
[m
Mountain View
California 94043-221
7
Computerized
Pool
Systems
N.,,oN.L
(415) 964-2201
fie..
POOL
INSTITUTt
INSTALLATION INSTRUCTIONS
TIME MASTER
POOL-SPA CONTROL SYSTEM
IMPORTANT SAFETY PRECAUTIONS:
All wiring must
be
performed by a qualified electrician.
Basic safety precautions and local codes should be observed when installing
and using this electrical equipment.
FiEAD AND FOLLOW ALL INSTRUCTIONS
EQUIPMENT LOCATION:
All electrical equipment must
be
located five feet or more from pool or spa with the
exception of the optional Spa-side Remote Control
1.
LX-10
Service Center at t!le equipment pad area
2. Time Master inside house or other weather-protected area
3. VOR-24 Valve
Opemtors at threeport valves
4.
WS5L Water Sensor at filter pump
5.
SS100 Spaside Remote Control (optionar) at spa site
LOW VOLTAGE CABLES:
Determine lengths of 22AWG low voltage cable needed between equipment
1.
6pair cable from Time Master to LX-10 Service Center.
2. 2 conductor cable from gas heater to LX-10 Service Center.
3. Water Sensor is provided with 10 feet of 2 conductor cable.
4.
Valve Operators are provided with 15 feet of 3 conductor cable
5. Spa-side Remote Control is provided with 100 feet of
4
conductor cable
Remote Control is also available with 50. 150 or 200 feet of cable
Install cable. Place cable in plastic or metallic conduit where it runs
underground
ihrough concrete, etc
NOTE: Never install low voltage cable and high voltage wires in the same
conduit A minimum distance of
12" must be maintained between parallel runs
of low voltage cable and AC current-carrying wires.
22AWG cable is available from Compool Corporation
PLUMBING:
Fol!ow recommended schematic (see next page) for location of threeport valves
2" dia. plumbing is advised to ensure optimum filter pump efficiency.
1. A
Y2" spa makeup line, (incorporating a Y2" manual gate or ball valve and, for elevated
spas,
aY2" checkvalve) should be provided around the retum valve(see schematic).
This enables clean water to be circulated to the spa while the system is in POOL
mode
2. Spa should be at or above the level of the pool If spa is attached to pool provide a
dam between the two bodies of water to allow spa overflow into pool If spa is not
attached to pool an overflow, sufficient in size to carry full pumpflow, must be
installed at water level in the spa