Pelco C256M-PSA (1/98) Outdoor Ceiling Fan User Manual


 
PM2010/PSA Ceiling Mount
C256M-PSA (1/98)
Installation Instructions
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 • FAX (1-559) 348-1120
1.0 DESCRIPTION The PM2010/PSA is a 10-inch (25.4 cm) ceiling mount specifically designed for use
with the PT780-24SL/PPSA pan and tilt unit.
2.0 INSTALLATION 1. Using the 8.5" (21.59 cm) end of the mount as a template, drill holes in the
ceiling for attaching the mount. Also drill a center hole with a diameter of 1.75"
(4.45 cm) to bring wiring through the ceiling.
2. Attach the mount to the ceiling (hardware not supplied). If necessary to pre-
vent water intrusion, apply sealant between the mount and ceiling.
3. Attach the PT780-24SL/PPSA to the mount (hardware not supplied). Bring all
wiring for the pan and tilt unit and camera enclosure through the center of the
mount.
3.0 SPECIFICATIONS Construction: Aluminum
Finish: Polyester powder coat
Dimensions: See Figure 1
Max. Weight Load: 125 lbs (56.62 kg)
Weight: Unit Shipping
3 lbs (1.35 kg) 4 lbs (1.81 kg)
(Design and product specifications subject to change without notice.)
Figure 1. PM2010 Dimension Drawing
1.75
(4.45)
6.00
(15.24)
10.00
(25.40)
8.50
(21.59)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
CAUTION
: Make sure
the mounting surface is
capable of supporting four
times the weight of the
mount, pan and tilt unit,
enclosure, and camera.