Panasonic LC-R063R4P Portable Generator User Manual


 
VRLA BATTERIES AUGUST 2005
VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.
For main and standby power supplies.
Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
LC-R063R4P
Specifications
Characteristics
Dimensions (mm)
Discharge characteristics 77°F (25°C)
(Note)
Duration of discharge vs. Discharge current
(Note)
Photo/Label for reference only.
(Note) The above characteristics data are average values obtained
within three charge/discharge. Cycles not the minimum values.
Terminal type: Faston 187
0.236 (6)
5.236 (133)
0.012 (0.3)
5.276
(134 )
1.5
0.5
+
-
2.362 0.039
(60 1)
+
-
5.12 (129.8)
1.319 (33.5)
0.398 (10.1)
1.339 0.039 (34 1)
+
-
+
+
-
+
-
0.398 (10.1)
0.059
0.020
+
-
7.2
6.9
6.6
6.3
6.0
5.7
5.4
5.1
4.8
4.5
4.2
3.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Terminal voltage (V)
1.7A
0.85A
0.34A
0.17A
3.4A
30
20
15
10
5
4
3
2
1.5
1
50
40
30
20
10
5
3
30 50 100 300 500 1 3 5 1
0
Discharge current
(mA) (A)
(Minute) (Hour)
Duration of discharge
104˚F (40˚C)
77˚F (25˚C)
32˚F (0˚C)
5˚F (-15˚C)
Battery case resin: Standard (UL94HB) Color is black.
Nominal Voltage
Rated Capacity (20 hour rate)
6V
3.4Ah
5.276 inches (134.0 mm
)
1.339 inches (34.0 mm)
2.362 inches (60.0 mm)
2.598 inches (66.0 mm)
1.37 lbs. (0.62 kg)
LC-R063R4P
Dimensions
Standard Terminals
and Resin
Length
Width
Height
Total Height
Approx. mass
UL94HB Faston 187
Capacity
(note)
77˚F (25˚C)
Self discharge
77˚F (25˚C)
1.5A
102%
100%
85%
65%
20 hour rate (170mA)
10 hour rate (300mA)
5 hour rate (540mA)
1 hour rate (2100mA)
1.5 hour rate discharge
Cut-off voltage 5.25 V
3.4Ah
3Ah
2.7Ah
2.1Ah
Internal Resistance
Fully charged battery
77˚F (25˚C)
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
91%
82%
64%
Approx. 30m
1.36 A or smaller
0.51 A or smaller
initial current
Control voltage
initial current
Control voltage
7.25V to 7.45V
(per 6V cell 25˚C
)
6.8V to 6.9V
(per 6V cell 25˚C
)
104˚F (40˚C)
77˚F (25˚C)
32˚F (0˚C)
5˚F (-15˚C)
Temperature
dependency
of capacity
(20 hour rate)
Charge
Method
(Constant
Voltage)
Cycle use
(Repeating
use)
Trickle use