User's Manual
GT15-75QBUSL
GT15-75QBUS2L
GT15-75ABUSL
GT15-75ABUS2L
Thank you for purchasing the GOT1000 Series.
GT15 BUS CONNECTION UNIT
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
MODEL GT15-75BUSL-U
MODEL
CODE
1D7M04
IB(NA)-0800298-J(1106)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
DANGER
CAUTION
[DESIGN PRECAUTIONS]
[INSTALLATION PRECAUTIONS]
[WIRING PRECAUTIONS]
[STARTUP AND MAINTENANCE PRECAUTIONS]
[DISPOSAL PRECAUTIONS]
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100mm
(3.94 inches) otherwise malfunctions may occur due to noise.
z Before mounting or dismounting this unit to or from the GOT,
always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction.
z Use this unit in the environment that satisfies the general
specifications described in the User's Manual for the GOT used.
Not doing so can cause an electric shock, fire, malfunction or
product damage or deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases.
Not doing so can cause a malfunction.
z Insert and fit the bus connection cable into the connector of the
unit to be connected until it "clicks".
After fitting, check for lift which can cause a malfunction due to a
connection fault.
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.
z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.Not doing so can cause unit or cable
damage due to dangling, moved or accidentally pulled cables or
can cause a malfunction due to a cable contact fault.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
z Dispose of this product as industrial waste.
CAUTION
DANGER
CAUTION
DANGER
CAUTION
DANGER
CAUTION
CAUTION
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For relevant manuals, refer to the PDF manuals stored in the CD-
ROM for the drawing software used.
© 2004 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
To configure a system meeting the requirements of the EMC and Low
Voltage Directives when incorporating the Mitsubishi GOT (EMC and
Low Voltage Directives compliant) into other machinery or
equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the
General Description included with the GOT used.
The CE mark, indicating compliance with the EMC and Low Voltage
Directives, is printed on the rating plate of the GOT.
Compliance with the Radio Waves Act (South
Korea)
This product complies with the Radio Waves Act (South Korea).
Note the following when using the product in South Korea.
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자
는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을
목적으 로 합니다 .
(The product is for business use (Class A) and meets the
electromagnetic compatibility requirements.
The seller and the user must note the above point, and use the
product in a place except for home.)
Packing List
The following items are included.
z Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the User's Manual for the GOT used, as they are precision
devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Detailed Manual
Manual name
Manual number
(Model code)
GT16 User's Manual (Hardware)
(Sold separately)
SH-080928ENG
(1D7MD3)
GT15 User's Manual
(Sold separately)
SH-080528ENG
(1D7M23)
GOT1000 Series Connection Manual
(Mitsubishi Products) for GT Works3
(Sold separately)
SH-080868ENG
(1D7MC2)
Relevant Manuals
Model Product Quantity
GT15-75QBUSL,
GT15-75QBUS2L,
GT15-75ABUSL,
GT15-75ABUS2L
Bus connection unit 1
Stickers 12
CAUTION
1. OVERVIEW
This User's Manual describes the GT15 bus connection unit
(hereinafter referred to as the bus connection unit).
Use the bus connection unit for making bus connection of the GOT.
Refer to the User's Manual for the GOT used for the applicable GOT.
2. SPECIFICATIONS
The performance specifications of the bus connection unit are
indicated below.
The general specifications of the bus connection unit are the same
as those of the GOT.
Refer to the User's Manual for the GOT used for the general
specifications of the GOT.
* When the GOT power is on, the internal current consumption is
included in the current consumption of the GOT.
When the GOT power is off, the internal current is supplied from
the power supply of the PLC system.
Select the used bus connection unit according to the connection
target and connection position.
<Bus connection unit selection example>
(1) Select the bus connection unit according to the connection target.
When using the bus connection, make the communication
settings to perform communication between the GOT and PLC.
Refer to GOT1000 Series Connection Manual for details of bus
connection.
Item
GT15-
75QBUSL
GT15-
75QBUS2L
GT15-
75ABUSL
GT15-
75ABUS2L
Interface
QCPU (Q Mode)
bus connection
QnA/ACPU
bus connection
Connector
IN1111
OUT - 1 - 1
I/O occupied
points
16 points
(I/O assignment:16
intelligent points)
32 points
(I/O assignment:
Special 32 points)
Internal current
consumption
(5VDC)*
0.44A 0.44A 0.12A 0.12A
Weight
0.13kg
(0.29lb)
0.14kg
(0.31lb)
0.13kg
(0.29lb)
0.14kg
(0.31lb)
(2) Select the bus connection unit according
to the GOT connection position.
Placed midway
: GT15-75QBUS2L/GT15-75ABUS2L
Placed at end
: GT15-75QBUSL/GT15-75ABUSL
GT15-75QBUS2L/GT15-75ABUS2L
QCPU (Q Mode), motion controller Q series
: GT15-75
Q
BUSL/GT15-75
Q
BUS2L
ACPU, QnACPU, motion controller A series
: GT15-75
A
BUSL/GT15-75
A
BUS2L
3. PART NAMES AND EXTERNAL
DIMENSIONS
Unit: mm (inch)
Dimensions of X when the bus connection unit is mounted to the
GOT
Unit : mm(inch)
*1 When the GT15-75QBUSL/GT15-75ABUSL is used, only the IN
side connector is available.
Model A
GT15- 75QBUSL 2.5(0.10)
GT15- 75QBUS2L 2.5(0.10)
GT15- 75ABUSL 4(0.16)
GT15- 75ABUS2L 4(0.16)
GOT GT16 GT15
15” 6.5 (0.26) 8 (0.31)
12.1” 5(0.20) 5 (0.20)
10.4” 8(0.31) 8(0.31)
8.4” 10 (0.39) 10 (0.39)
5.7” 10 (0.39) 10 (0.39)
137(5.39)
102(4.02)
4)
4)
5)
*1
2) 1)
17.5
(0.69)
Back view
3)
X
GOT
A
4. INSTALLATION PROCEDURE
The installation procedure for the bus connection unit is explained
using the GT1575.
(1) Power off the GOT.
(2) Remove two extension unit covers of the GOT.
(3) Fit the bus connection unit in the GOT case.
No. Name Description
1) Bus connector (IN side)
Connector for connecting the
bus connection cable (IN side)
2)
Bus connector (OUT
side)
Connector for connecting the
bus connection cable (OUT side)
3) Extended connector
Extension connector mounted to
the GOT
4) Mounting screw
Screw (M3 screw) for fixing the
unit to the GOT
5) Rating plate -
(4) Fasten the bus connection unit by tightening its mounting screws
(4 places) with tightening torgue 0.36 to 0.48 N•m.
(5) After tightening screws, attach the supplied stickers to avoid
receiving electrostatic.
Warranty
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
• Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A.
Tel : +1-847-478-2100
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Germany Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
U.K Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.
Tel : +44-1707-276100
Italy Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy
Tel : +39-039-60531
Spain Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80,
E-08190 Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France
Tel : +33-1-5568-5568
South Africa Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando, South Africa
Tel : +27-11-928-2000
Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, Hong Kong
Tel : +852-2887-8870
China Mitsubishi Electric Automation (China) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
Shanghai 200003, China
Tel : +86-21-6120-0808
Taiwan Setsuyo Enterprise Co., Ltd.
6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea Mitsubishi Electric Automation Korea Co., Ltd.
1480-6, Gayang-dong, Gangseo-ku Seoul
157-200, Korea
Tel : +82-2-3660-9552
Singapore Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building, Singapore 159943
Tel : +65-6470-2460
Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd.
Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd,
T.Kannayao, A.Kannayao, Bangkok 10230 Thailand
Tel : +66-2-517-1326
Indonesia P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A/Utara
No.1 Kav. No.11 Kawasan Industri Pergudangan
Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia
Tel : +62-21-6630833
India Messung Systems Pvt, Ltd.
Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari,
Pune-411026, India
Tel : +91-20-2712-3130
A
ustralia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan, June 2011.