Mounting the Scale
A maximum of two support pillars may be screwed together to allow for sufficient adjustment of the scale. If two pillars
are insufficient to enable the scale to be mounted, then additional brackets will be necessary. These brackets must be
sufficiently rigid to eliminate any axial movement of the scale.
Loosely fit the support link/pin assembly onto the pillar and pass the scale through the reader head and into the support
pin. While gently sliding the scale forward and back 25 - 50mm (1 - 2") through the support pin, carefully tighten the hex
screws on the support link, ensuring that the scale slides smoothly through the reader head and into the support pin. If
any interference is detected then fully loosen the hex screws on the support link and repeat this step.
Note: Do not force the scale through the Support Pin.
IMPORTANT WARNING:
THE CENTER LINE BORE OF THE READER HEAD MUST BE IN DIRECT ALIGNMENT WITH THE
CENTER LINE BORE OF THE SUPPORT PIN. PERMANENT DAMAGE TO SCALE AND/OR
ERRONEOUS READINGS WILL OCCUR IF THIS WARNING IS NOT FOLLOWED (REFER TO FIGURE 4.2).
Remove the scale from the reader head and traverse the machine to its full extent in the opposite direction.
Full extent means hand winding past electrical limits.
Assemble the scale support link to the scale support pin leaving approximately 3mm (1/8") gap between the bottom of
the pin shoulder and the top of the link.
Slide the link/pin assembly onto the scale making certain that there is sufficient clearance between the reader head and
the support link to prevent damage to the reader head cable. Do not secure the support pin to the scale at this time.
Transfer punch through the support link and into the machine casting. It is important that the support link be kept square
to its mounting surface at all times.
Figure 4.2 - Reader head and bracket alignment
Newall Measurement Systems