6 INSPECTION AND TROUBLESHOOTING
Invacare
®
TheraPure™ Side Entry Whirlpool Tubs 32 Part No. 1167457
6.2 Troubleshooting
If problems are not remedied, contact technical support at 1-800-668-2337, Extension 2.
SYMPTOMS FAULTS SOLUTION
Hydromassage System
System will not start No electrical power to tub Check and reset breaker
Switch air hose disconnected Reconnect hose to switch and controller
System is ineffective Water deposits in whirlpool jets Disassemble and clean whirlpool jets
System is noisy Whirlpool jets are turned on without water
completely covering the jet assemblies
Turn off the whirlpool jets. Add water to the tub to
completely cover the jet assemblies and test the whirlpool
function again.
Tub Operation
No water flow Water supply turned off Turn on water supply
Restricted water flow Water temperature control valve Inspect and clean the water temperature control valve.
Refer to the Moen service manual at www.moen.com.
Search for Model 3371 ExactTemp Temperature Control
Valve, Service Manual Number 153768.