Hunter Fan 27210 Outdoor Ceiling Fan User Manual


 
Hunter Universal Fan & Light Remote Control
Models 27224, 27210
Ratings: 120 VAC, 60 Hz,1.0 Amp Fan Receiver Weight: 6 oz.
300 Watts incandescent light
Read and Save these Instructions
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with national and local electrical
codes. If you are unfamiliar with the wiring codes, you should use a
qualied electrician.
To avoid overheating and possible damage to other equipment, do not
install to control a receptacle, uorescent light xture, motor operated
appliance, or transformer-supplied appliance. Use only to control one
paddle-blade ceiling fan and incandescent light xture.
Notes:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the fol-
lowing two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
2. Industry Canada: Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
3. This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
4. In the case of a power outage, the fan and light connected to this remote will turn off
and remain off after the power resumes.
5. For use only with electrically reversible ceiling fans rated at 1.0 amp or less, and fan
incandescent light kits rated at 300 watts or less.
6. Not for use with shaded-pole motors. Not recommended for use with the Hunter
Original®. For Hunter Original® series fans, use Hunter control model numbers 27187,
22691, or 27189.
7. Medium and Low fan speeds are determined by the control and thus may vary from
the factory settings due to normal motor variations.
8. For use with Hunter Hanging systems (excludes Hunter Original) on angled ceilings
up to 34 degree pitch ceilings.
9. Not for use in applications where the fan does not have a wall switch
Any changes or modications to this equipment not expressly approved by Hunter Fan
Company will void the user’s authority to operate the equipment.
Before Installing the Control:
1. Use the pull chain switch to set the fan speed to the HIGH
position before installation. Do not use the pull chain to change
the fan speed after installation, as damage to your ceiling fan or
universal control may result. The speed of the fan should only be
changed by the Hunter control.
2. Set the ceiling fan light kit to the ON position before installa-
tion. The light level should only be changed by the Hunter control.
Receiver Installation:
1. Disconnect power to the ceiling fan and light kit at the main electrical panel. Remove
fuse or move circuit breaker to the OFF position.
2. IMPORTANT! Before installing this control, Change the position of the jumpers in
the transmitter and the DIP switches in the receiver. Be sure the position of the jumper
in the transmitter matches the position of the DIP switches in the receiver. If they don’t
match, the controller will not function. Select different combinations of settings to
prevent misoperation due to other remote control fans.
3. IMPORTANT! If your ceiling fan light kit is using incandescent bulbs, then slide the
CFL / INC switch to the INC position. Refer to Figure 1. If your ceiling fan light kit is
using compact uorescent light bulbs (CFL), then slide the CFL / INC switch to the
CFL position. NOTE: When the switch is in the CFL position, the dimming feature is
disabled, and you will not be able to dim the light bulbs. This feature is to protect both
your bulbs and your receiver as CFL bulbs are not able to dim and will malfunction if
dimming is attempted.
4. Determine your ceiling fan mounting type (Figure 2). Most installations will be one of
these four types: Canopy Hanger, Hunter Hands-Free
TM
Canopy, Low Prole Styles I
and II, or Bracket Hanger.
5. Install the ceiling fan according to its instructions, up to the point of making the
electrical connections. Connect receiver to ceiling fan according to the mounting type
as instructed in Figure 2.
6. If the fan is already installed, turn the power OFF at the main electrical panel.
Reverse the installation procedure according to the fan instructions, to the point of
disconnecting the fan wiring. Connect the receiver to the ceiling fan according to the
mounting type as instructed in Figure 2.
7. Use the 2 large wire connectors supplied to connect the receiver and house wiring,
then use the 3 small wire nuts supplied to connect the receiver and ceiling fan wiring.
Refer to the Wiring Diagram in Figure 3.
8. Be sure the antenna is positioned securely, so it can not interfere with the ceiling
fan motor. Refer to Figure 2. Do not modify or damage the antenna wire, as control
performance may be reduced. After securing the receiver, antenna, and wiring, nish
hanging the ceiling fan according to its instructions.
9. Restore power at main electrical panel.
Transmitter Installation:
1. Install the 12 volt alkaline battery (A23 or equivalent) inside the hand-held transmit-
ter, after setting the dip switches to match the dip switches in the receiver.
2. Mount the remote holder over the ceiling fan’s wall switch using the existing wall
plate screws. Refer to Figure 4.
3. The transmitter can be placed on the remote holder for convenience or safekeeping.
Fan Installation Types:
NOTE: Some fans may have considerable excess lead wire. For easier canopy
installation, cut the excess wire leaving a minimum of 6 inches remaining. Restrip the
fan lead wires 1/2 inch. Place remaining excess wire into the ceiling electrical box as
needed.
Canopy Hanger (Fig. 2-A): Place receiver in canopy. Connect wiring as shown in Fig.
3. Extend antenna through one of the ceiling plate openings (approximately 3–6˝).
Hunter Hands-Free™ Canopy (Fig. 2-B): Connect wiring as shown in Figure 3. Place
receiver inside mounting bracket. Extend antenna above the ceiling mounting bracket
(approximately 3–6˝).
Low Prole Style I (Fig. 2-C): Secure receiver to the fan plate above the motor with UL
listed cable ties (not included). Connect wiring as shown in Figure 3. Extend antenna
through one of the ceiling plate openings (approximately 3–6˝).
Low Prole Style II (Fig. 2-D): Secure receiver to the ceiling mounting bracket with UL
listed cable ties (not included). Connect wiring as shown in Figure 3. Extend antenna
above the ceiling mounting bracket (approximately 3–6˝).
Bracket Hanger (Fig. 2-E): Starting with the antenna wire, slide receiver inside
mounting bracket. If a ground wire mounting screw prevents the receiver from sliding
into the bracket, move ground wire and screw to an unused hole at the top of the
bracket or secure with a canopy mounting screw. The bracket must remain properly
grounded. Connect wiring as shown in Figure 3. Extend antenna above the receiver
(approximately 5–8˝).
Cable Tie Routing for Low Prole Fans (Figs. 2-C, 2-D): Insert cable tie through open-
ings as shown. DO NOT insert the cable
tie through the inside of the receiver. The cable tie
can be placed across the length or width of the
receiver to best match your fan installation type.
Fig. 2-A Fig. 2-B
Figure 2
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Bracket
Receiver
Receiver
Placement
On Motor
Fan
Motor
Motor
Mounting
Plate
Antenna
Ceiling
Bracket
Receiver
Fan Body
Antenna
Antenna
Receiver
Canopy
Bracket
Canopy Hands-Free
TM
Canopy Low Profile I Low Profile II Bracket Hanger
Fig. 2-C Fig. 2-D
Fig. 2-E
1. Light Operation:
• Turn ON wall switch, the light will turn ON at maximum brightness.
• Press and quickly release the light key on the hand held remote to turn the light OFF
or ON. (Light will come ON at maximum brightness.)
• Press and hold the light button for more than 1 second to turn the light ON and
decrease from maximum brightness to OFF.
• Release the light button when the desired light level is reached.
• Continue to hold the light button to repeat the cycle. (Maximum–light level decrease–
OFF)
• While the light is ON, holding the light button will decrease the light brightness.
• Turning the light OFF resets the dimming function. The next press of the light button
will start at maximum brightness.
2. Fan Operation:
• Press the High, Medium, or Low speed buttons to turn the ceiling fan ON at the
desired speed.
• Press the fan OFF key to turn the ceiling fan OFF.
For best fan operation: Start the fan on High, and then select the desired speed.
AC
Power
In
Light
Kit
Red
Black
White
Fan
White/Neutral
Black/Hot
Common
Antenna
Figure 3 Wiring Diagram
TROUBLESHOOTING
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control (“Control”): Your Control is warranted to be free from defects in material and
workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace
it free of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH
CONTROL. This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation, modications, or dam-
age to the Control while in your possession, or unreasonable use. This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty
batteries. To obtain a replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy.
#400, Memphis, Tennessee 38016. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE
ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.
Symptom
Figure 1
Transmitter Back
Receiver Back
DIP Switches
Antenna
Jumpers
CFL/INC Switch (Shown in
incandescent position)
Possible Causes Solution
1. No functions operate.
2. Operates only at close range.
3. Inconsistent operation.
Main Power not restored. Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
Signal blocked from reaching receiver. Extend antenna into ceiling box, or move it for better reception.
Signal partially blocked from reaching
receiver.
Change dip switch settings to a different code in both
Transmitter and Receiver.
Fan pull chain not set to High.
Light pull chain not set to ON.
Receiver wiring incorrect.
Transmitter and receiver dip switches do
not match.
Battery too weak.
Set fan pull chain to High speed.
Set light kit to ON.
Verify wiring connections.
Set transmitter and receiver to same dip switch setting.
Replace with new, 12 volt alkaline battery.
Battery too weak. Replace with new, 12 volt alkaline battery.
RF interference.
Continuing RF interference.
Extend antenna into ceiling box, or move it for better
reception.
Turn OFF wall switch for 5 seconds, then turn back ON.
44023-01 03/04/2011
Printed in China and Taiwan
CFL
4 3 2 1
4 3 2 1
4 3 2 1
4 3 2 1
4 = off (apagado)
3 = on (encendido)
2 = on (encendido)
1 = on (encendido)
4 = off (apagado)
3 = on (encendido)
2 = off (apagado)
1 = on (encendido)
Fan High
Fan Medium
Fan Low
Fan Off
Light