Heath Zenith SL-4190 Landscape Lighting User Manual


 
Mode: On-Time Works: Day Night
Test 5 Seconds x x
Auto 1, 5, or 10 Min x
Manual To Dawn* x
Accent 3,6 Hr, to Dawn x
Motion Sensing
Diecast Lantern
SL-4190 Series
Features
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight
hours.
Requirements
• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the control
must be wired through a switch.
Some codes require installation by a
qualified electrician.
© 2006 DESA Specialty Products™ 595-5628-07
OPERATION
* resets to Auto Mode at dawn.
Set the ON-TIME switch
on the bottom of the
cover plate to TEST.
TEST 1 5 10 MIN
Set ON-TIME switch to
1, 5, or 10 minutes.
1 Second
OFF then...
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only
with the ON-TIME switch in
the 1, 5, or 10 position.
... back on.
Mode Switching Summary
D
UALBRITE
®
Dimmer Control
Light comes on half bright for selected time
after dusk (3 hr., 6 hr., until dawn). If motion
is sensed, the light turns on full bright for the
ON-TIME (1, 5, or 10 minutes) then returns
to dim mode.
This package includes:
• Lantern
• Easy to use universal mounting bracket
(X-Bar)
• Mounting hardware
• Wire nuts
ON-TIME Switch at 1,
5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes,
turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1
1
/
2
minutes for the circuitry to calibrate.
TEST
AUTO
MANUAL MODE
TEST 1 5 10 MIN