IMPERIAL GAS LOG SET INSTALLATION INSTRUCTIONS
8. Intermittent Pilot Ignition
a. ApplianceRequirements:Thisappliancedoesnotrequire110VACsupplyforoperation.
1) A wiringdiagramisshowninFigure13.Abatterypackissuppliedwiththeappliance.Thisappliance
requirestheuseoftwoD-cellbatteries(notsuppliedwiththeappliance)foroperation.
2) Intheeventofapoweroutage,theappliancewillcontinuetooperateifbatteriesareinstalledinthebattery
pack.
Figure 13 - “M” Series Intermittent Pilot Wiring Diagram
b. BatteryReplacement
1) AccessCover-Removetheaccesscoverbylocatingthetwohandtabsoneithersideoftheaccesscover.
Slidetheaccesscovertotherightapproximately1”todisengageitfromthebase.SeeFigure14.
2) BatteryPack-Locatethebatterypackandslideitforwardoutofthebase.SeeFigure15.Replacebatteries
andreinstallthebatterypackintothebase.Thebatterypackisheldinplacebyamagnetlocatedonthe
basepan.
Figure 14 - Access Cover Removal Figure 15 - Battery Replacement
ON/OFF Switch