Hearth and Home Technologies FI36ML Log Splitter User Manual


 
4 33734 Rev J 1/11
Thesegaslogsetsareavailablewithdifferentvalvesystems.TheFi36S,Fi36SL,Fi42SandFi42SLsetsuseaseparate
regulatorandvalvesystem,andtheFi36M,Fi36ML,Fi42MandFi42MLsetsuseacombinationcontrolwithanintermit-
tentpilot.Bothvalvesystemsareavailableinnaturalorpropanegas.Onlythe“M”Seriescanbeusedwithanoptional
remotecontrol(RC-BATT-HTL).
Conversionkitstoconvertfromnaturalgastopropaneorfrompropanetonaturalgasareavailable.
• Theconversionkitsforall“M”serieslogsetsare:
- DCKP toconvertfromnaturalgastopropane
- DCKN toconvertfrompropanetonaturalgas.
• Theconversionkitsforall“S”serieslogsetsare:
- CKMP toconvertfromnaturaltopropanegas
- CKMN toconvertfrompropanetonaturalgas.
TheseHEATILATOR®gaslogsetsandcomponentshavebeentestedandwilloperatesafelywheninstalledinaccor-
dancewiththisinstallationmanual.Thisdecorativeapplianceisahighlyengineeredsystem.UnlessyouuseHEATILA-
TOR®componentswhichhavebeendesignedforthesystem,youmaycreatearehazard.
Gaspressure
BTU/hr.Input
Model No. BTU/Hr. Input Orice
Fi36M
60,000
.152
Fi36ML .093
Fi36S .169
Fi36SL .093
Fi42M
80,000
.182
Fi42ML .110
Fi42S .228
Fi42SL .110
Gas Pressure
Inletgassupplypressure(NG) 4.5(min)-7.0(max)in.w.c.
Optimalmanifoldpressure(NG) 3.5in.w.c.
Inletgassupplypressure(LP) 11.0(min)-14.0(max)in.w.c.
Optimummanifoldpressure(LP) 10in.w.c.