Hearth and Home Technologies FI36M Log Splitter User Manual


 
1/11 33734 Rev J 19
IMPERIAL GAS LOG SET INSTALLATION INSTRUCTIONS
O. TROUBLESHOOTING - “S” SERIES
Symptoms Possible Causes Corrective Action
1 Matchwillnotlightpilot. a. Maingasshutoffvalveclosed. Makesurethattheshutoffvalvelocatedonthe
incominggaslineisopen.
b. Air in the gas line. Lightamatch.Turnvalveknobto“PILOT”position
anddepress.Keepmatchnearpilotburneruntilit
lights.
c. Valveknobisin“OFF”position Turnvalveknobto“PILOT”positionanddepress.
Keepmatchnearpilotburneruntilitlights.
d. Pilotoriceisplugged,not
allowinggastoow
Thisrepairrequirestoolsandsomedegreeof
experience.Callaqualiedservicetechnician.
e. No gas supply to the appliance. Checktheplumbingtoensuretheappliancehas
beenhookeduptothegassupplyline.
2 Pilotlights,butwillnotstaylit
aftercarefullyfollowinglighting
instructions.
a. Thermocoupletootightortoo
loose.
Thermocouplemustbeattachedtothevalvenger-
tight,plusa1/8turnwithawrench.
b. Weakpilotame. Pilotamemustengulfthethermocouple.Clean
and/oradjustpilotformaximumameimpingement
onthethermocouple.
c. Defectivethermocouple. Checkthethermocouplewithamillivoltmeteras
follows:Disconnectthethermocouplefromthe
valveandconnecttheredleadofthemetertothe
silverendofthethermocouple.Nowconnectthe
blackleadofthemetertothecoppertubingofthe
thermocouple.Lightthepilotandkeeptheknob
depressedwhiletakingreadings.Themeterreadings
shouldbegreaterthan14mV.Ifnot,replace
thermocouple.
3 Pilot“ON”.Nogastomain
burner,valveknob“ON”.
a. Ablockageispreventinggas
ow.
Inspecttheburneroriceforobstruction.Calla
qualiedservicetechnician.
b. Defective valve. Replacegasvalve.Callaqualiedservice
technician.