Hearth and Home Technologies FI36M Log Splitter User Manual


 
12 33734 Rev J 1/11
G. Glass Doors
Ifyourreplaceisequippedwithaglassdoor,theglassdoorsshouldbeinthefullopenpositionwhentheapplianceis
operating.Operatingthereplacewiththeglassdoorsclosedwillblocktheradiantheatoutputofthereplaceandmay
causeincompletecombustionofthenaturalorpropanegasfuel.
IMPORTANT! Alwaysensurethatthewirereplacescreenisclosedwhenthereplaceisoperating.
Yourgaslogsrequirelittlecare.Keeptheburnerassembly,logsandburnerareasurroundingthelogscleanbyvacuum-
ingorbrushingwithadrypaintbrushatleasttwiceayear.
• Alwaysturnoffthegastothepilotbeforecleaning.Forrelighting,refertolightinginstructionslocatedon
pages 10 and 11.
• Alwayskeeptheapplianceclearandfreefromcombustiblematerials,gasoline,andotherammablevapors
and liquids.
• Neverobstructtheowofcombustionandventilationair.Keepthefrontoftheapplianceclearofallobstacles
andmaterials.
• Leaveclearanceofatleast36”fromthefrontofthereplace.
• Theairshuttershouldnotbeblocked.
CAUTION:
The logs can get very hot. Handle only when they
are cool.
CAUTION:
After burning, the log becomes fragile, so take care
in handling.
Thereplaceventingsystemisdesignedandconstructedtodevelopapositiveowadequatetoremoveuegasestothe
outsideatmosphere.Seeventedreplaceinstallationinstructions.
1. A spillage test must be made before the installed appliance is left with the consumer.
a. Closealldoorsandwindowsinthehome.
b. Lightthelogset.
c. Afterthreeminutes,testwithasmokematch,smokecandle,stickincense,orcigarette1”belowthetop
oftheopening(lintel)movingacrossthefullwidth.SeeFigure16.Ifspillage(smokedrawnintotheroom)
occurs,itwillmostlikelybenearthetop,outsidecorners.
Figure 16 - Checking for Spillage
H. Cleaning
I. Inspecting the Venting System