Flymo 450 Trimmer User Manual


 
CABLES
IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres
length maximum.
Maximum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR HEDGETRIMMER IS SUPPLIED
WITH CABLE WIRED DIRECTLY INTO THE
PRODUCT.
1.Mains Cables and Extension Cables are avail-
able from your local Approved Service Centre.
2.Do not wire an extension cable directly to your
product yourself. Please contact your local
Approved Service Centre for further informa-
tion on the connectors and kits available.
3.Only use extension cables specifically
designed for outdoor use.
CONNECTORS
IMPORTANT
Connectors are suitable for use with 2 core
cable only. Under no circumstances should
these connectors be used for earthed prod-
ucts.
All connectors and cables are of splashproof
construction. They are not waterproof and
must not be left outside permanently nor
should they be submerged or immersed in
water. Do not let cable lay or trail through
pools of water or splashed with water from
hose pipes.
MAINS PLUG REPLACEMENT
IMPORTANT
If the plug supplied is cut off it should be
destroyed. There is an electric shock haz-
ard if a cut off plug is inserted into a 13
amp socket.
1.No earth required. Our products are double
insulated to EN50144 and under no circum-
stances should an earth be connected to any
part of the product.
2.Ensure the mains voltage suits your product
3.IMPORTANT!
The wires in the mains lead are coloured in
accordance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured BLUE must be
connected to the Terminal which is marked
with the letter 'N' or coloured BLACK.
The wire which is coloured BROWN must be
connected to the Terminal which is marked
with the letter 'L' or coloured RED.
4.It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5.If in doubt consult your local Service Repairer
or qualified electrician before the machine is
used.
6.A 13 Amp fuse must be fitted to the Mains
Plug.
7.The normal plug fuse and household fuse only
protect the electrical equipment and are not a
safeguard against electrocution.
If your product is hard wired i.e. non-
detachable mains electric cable, a conver-
sion kit and extension cable is available
from all Approved Service Centres which
can be found in your local Yellow Pages.
Assembly of Handguard.
1. Insert Handguard into slot as illustrated in
figure A, ensuring that it is securely locat-
ed.
DO NOT USE THE PRODUCT WITH
-
OUT FITTING THE HANDGUARD
Assembly
A