Dynasty Spas MC-MP-DY4 Hot Tub User Manual


 
Quick Reference Card
Troubleshooting
Pumps have started up for
one minute on several
occasions and "Filter Cycle"
icon is flashing.
Not a bug but a feature!
Our Smart Winter Mode
protects your system from
the cold by automatically
turning the pumps on for
one minute several times
a
day to prevent water from
freezing in pipes.
Water temperature is
displayed.
Water temperature in the
spa has reached 112˚F
(44˚C).
Do not enter the water!
Allow water to cool down.
The system will reset au-
tomatically when water
reaches 109˚F (43˚C).
Call your dealer or service
supplier if problem persists.
3 flashing dots are dis-
played.
A problem has been de-
tected.
Do not enter the water!
Check and open water
valves. Clean filters if nec-
essary. Check water level.
Add water if needed.
Shut power off and power
your spa up again to reset
the system.
Call your dealer or service
supplier if problem persists.
The display is flashing.
A power failure has
occurred. Press any key
to reset the system, then
reprogram all desired
parameters.
Press and hold Light key for 5 seconds to
display water temperature in either Fahrenheit
(˚F) or Celsius (˚C).
Temperature display unit:
The display toggles every 5 seconds alternately
showing the hourly time and the current water
temperature.
Time & temperature display:
Turning the light on:
The Quick Reference Card provides a quick overview of your spa's main
functions and the operations accessible with your digital control pad.
MC-MP-DY4 Spa Pack
Press Pump 1 to turn Pump 1 on at low
speed. Pressing a second time turns Pump 1
to high speed. A third time turns Pump 1 off.
When at high speed, a built-in timer turns
pump off after 20 minutes and when at low
speed after 2 hours, unless it has been
manually deactivated.
The "Pump 1" icon lights up when
Pump 1 is on at high speed. It flashes
when Pump 1 is on at low speed.
Starting Pump 1:
Starting Pump 2:
Press Pump 2 once to turn Pump 2 on at low
speed. Pressing a second time turns Pump 2
to high speed. A third time turns pump off.
A built-in timer turns pump off after 20 mi-
nutes, unless manually deactivated first.
The "Pump 2" icon lights up when
Pump 2 is on at high speed. It flashes
when Pump 2 is on at low speed.
Press Blower to turn blower on at high speed.
Press a second time to turn blower to low
speed. A third time turns blower off. A built-in
timer turns blower off after 20 minutes, unless
manually deactivated first.
The "Blower" icon lights up when
blower is on at high speed. It flashes
when blower is on at low speed.
Starting the blower:
Use Up or Down arrow key to regulate water
temperature. The temperature setting will be
displayed for 5 seconds to confirm your new
selection.
The "Set Point" symbol indicates the
desired temperature, NOT the current
water temperature!
Water temperature can be adjusted by 1˚ in-
crements from 59 to 104˚F (15 to 40˚C).
Setting water temperature:
When water temperature is 1˚F (0.5˚C)
lower than the Set Point, the heater will
automatically turn on until water tempera-
ture reaches Set Point plus 1˚F (0.5˚C).
The "Heater" icon lights up when the
heater is on. It flashes when there is a
request for more heat but the heater
has not yet started.
Automatic water heater start:
Inverted display:
Press and hold Pump 2 for 5 seconds to invert
the display. Note that the ˚F or ˚C icon is not
displayed in reverse mode. Follow the same
procedure to return to default mode. If a
power-up occurs, the display always returns
to default mode.
Pressing Light key once turns light on at high
intensity. Pressing a second time turns light to
low intensity. A third time turns light off.
A built-in timer turns light off after 2 hours,
unless it has been manually deactivated.
The "Light" icon is displayed when
light is on at high intensity. It flashes
when light is on at low intensity.
Fiber Box Option: If spa has an optional fiber
box only, pressing Light key turns fiber box
(motor & light) on. Pressing again turns fiber
box motor off but leaves light on. A third time
turns both motor and light off. A built-in timer
turns fiber box off after 2 hours, unless it has
been manually deactivated. The "Light" icon is
displayed when fiber box light is on. It flashes
when fiber box motor and light are on at the
same time.
LED Light Option: If spa has an optional LED
light, Press Light key to turn LED lights on. To
advance to the next color/display setting, press
Light key twice. The LEDs will go off with the
first press, then back on in the next setting with
the second press. If the LEDs remain off for
more than 5 sec., the color/
display sequence will reset and start back at
the beginning the next time the Light key is
pressed. Color/ display sequences are:
1• LEDs light up and slowly cycle through all
six colors. The slow cycle restarts at the
beginning and repeats.
2• LEDs light up and remain on in Aqua.
3• LEDs light up and remain on in Purple.
4• LEDs light up and remain on in Blue.
5• LEDs light up and remain on in Gold.
6• LEDs light up and remain on in Green.
7• LEDs light up and remain on in Red.
8• LEDs light up for 2 sec., flash off, then
flash on in the next color until all six colors
have been displayed. The flashing cycle
then repeats itself.
9• LEDs flash on/off quickly for a strobe light
effect. A built-in timer turns lights off after
2 hours unless manually deactivated first.
The "Light" icon is displayed
when light is on.
The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set
Point or if a pump has been started manually. The "Filter" icon will blink (on 0.5 second,
off 0.5 second, on 0.5 second, off 1.5 seconds).