PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
9.5
Inline Remote Blowers
ILB8, ILB10
ISOMETRIC VIEW
NOTE:
1. The ILB8 and ILB10 inline blowers are only
approved in updraft (hood) applications.
Model
No.
“A” Overall
Chassis Width
“B” Overall
Chassis Height
“C” Overall
Chassis
Length
“D” Duct
Diameter
Dedicated
Circuit
Required
Maximum
Duct Length
Total
Connected
Load
Blower
Rating
Approximate
Shipping
Weight
ILB8 10 5/8” (270mm) 10 1/2” (267mm)
5” (127mm)
8” (203mm)
Refer to
Ventilator
Specifications
Max. 60
Equivalent
Straight Feet
0.1kW (1A) 600 CFM 12 lbs.
ILB10 12 5/8” (321mm) 12 1/2” (318mm) 10” (254mm) 0.2kW (2A)
1100
CFM
16 lbs.
"A"
"B"
Attachment
Surface
OVERALL DIMENSIONS FRONT VIEW
ROTATION
AIRFLOW
120V, 60Hz, 15A POWER SUPPLY
CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT
FAN MOTOR
GR
N
DACOR P/N 85829
WIRING DIAGRAM, ILB-8
M
BK
L
"C"
"D"
Attachment
Surface
Electrical
Access Panel
OVERALL DIMENSIONS SIDE VIEW
TOP VIEW
1/1