HOW TO REMOVE AN OBJECT
FROM THE AIR INTAKE
_WARNING: Stop the unit and
disconnect from the power source be-
fore opening the inlet cover. The mo-
tor must be stopped and the impeller
blades no longer turning to avoid seri-
ous injury from the rotating blades.
1. While holding the inlet cover open,
remove the vacuum tubes. The in-
let cover must be held open through
all remaining steps.
2. Carefully reach into the vacuum
opening and clear out the air intake
area. Clear all debris from impeller.
3. Inspect the impeller for cracks. If
cracked or damaged, do not use the
unit. Have parts replaced by your
Sears Service Center. Do not at-
tempt to replace them yourself.
PARTS AVAILABLE
Blower Tube/Nozzle .... 530403612
Vacuum Tube Set ...... 530402499
Inlet Restrictor ......... 530402045
Collection Bag ......... 530402533
Gutter Kit ................ 71-79997
Safety Glasses ........... 71-85707
Extension Cord ........... 71-5702
all.WARNING: Perform the follow-
ing steps after each use:
• Stop unit and disconnect from the
power source.
• Store the unit in a stable location. Se-
cure the unit before transporting.
• Store unit with all guards in place.
Position unit so that any sharp object
cannot accidentally cause injury.
• Store unit well out of the reach of chil-
dren.
Prepare unit for storage at the end of
the season or if it will not be used for
30 days or more.
BLOWER STORAGE
• Disconnect from tile power source.
• Clean the entire unit.
• Open inlet cover and clean any dirt,
grass, or debris that has collected. In-
spect the blower and all tubes. Close
and make sure the cover is latched.
• Clean air vents and air inlet of debris.
• Store your unit and extension cord in a
well ventilated area and covered, if
possible, to prevent dust and dirt accu-
mulation. Do not cover with plastic.
Plastic cannot breathe and may cause
condensation and eventual rust or cor-
rosion.
• Check entire unit for loose screws,
nuts, and bolts. Replace any dam-
aged, worn, or broken parts.
TROUBLESHOOTING TABLE
WARNING: Always stop unit and disconnect from the power source before
performing all ofthe recommended remedies below except remedies that re-
quire the unit to be operating.
SYMPTOM CAUSE REMEDY
Unit fails to 1. Switch inthe OFF (0) position. 1. Move switch to the LOW speed (1)
operate, or HIGH speed (2) position.
2. Extension cord disconnected. 2. Reconnect extension cord.
3. Circuit breaker tripped, or 3. Reset circuit breaker or
fuse blown, fuse.
4. Mechanical failure. 4. Contact Sears Service (see back
cover).
Unit 1. Mechanical failure. 1. Contact Sears Service (see back
vibrates cover).
abnormally.
Impeller will 1. Debris inair intake area. 1. Clean unit. Remove any debris.
not turn 2. Mechanical failure. 2. Contact Sears Service (seeback
freely, cover).
10