9. Once the Engine is running, simply connect the 120 volt appliances, tools, and
equipment into the 120V AC Outlets (4) and/or connect a 12 volt appliance, tool,
or equipment into the 12V DC Outlet (8). (See Figure E.)
10. IMPORTANT: If Engine speed or voltage fluctuates with a load below 250
Watts, move the Engine Choke Lever to the “HALF-CHOKE” position.
(See Figure G.)
11. When finished using the Generator, disconnect all electrical loads. Turn the
Engine Power Switch (14) to its “OFF” position to stop the Engine. Then, close
the Engine Fuel Valve Lever. (See Figures E and F.)
INSPECTION, MAINTENANCE, AND CLEANING
1. WARNING! Always make sure the Power Switch (14) of the Engine is in its
“OFF” position prior to performing any service, maintenance, or cleaning of the
Generator or Engine. (See Figure E.)
2. Before each use, inspect the general condition of the Generator and Engine.
Check for loose screws, misalignment or binding of moving parts, cracked or
broken parts, loose hose connections, and any other condition that may affect
the safe operation of the Generator and Engine. If abnormal noise or vibration
occurs, have the problem corrected before further use.
Do not use damaged equipment.
3. Generator maintenance: Keep the Generator clean and dry at all times. The
Generator should not be operated or stored in locations that include excessive
moisture, dust, flammable or corrosive vapors. If these substances are on the
Generator, clean with a cloth or soft brush. Do not use a garden hose or anything
with liquid to clean the Generator. Liquid may enter the cooling air slots and could
damage the interior workings of the Generator.
4. Engine maintenance: Refer to the Engine manufacturer’s
“Operation,
Maintenance, and Parts”
manual (included) for detailed information about starting,
running, stopping, and maintaining the Engine.
5. When storing the Generator, make sure to store the unit in a clean, dry, safe
location out of reach of children and other unauthorized people.
6. CAUTION! All maintenance, service, or repairs not mentioned in this
manual must only be performed by a qualified service technician.