Chicago Electric 67561 Portable Generator User Manual


 
Page 8For technical questions, please call 1-800-444-3353.SKU 67561
BASIC SPECIFICATIONS
Fuel
Type
91+ octane premium
unleaded gasoline
Capacity 4 Gallons
Engine
Oil
Type
SAE 10W-30 above 32°F
SAE 5W-30 at 32°F or below
Capacity
2/3 Quart with Low Oil
Shutdown Sensor
Spark Plug Gap 0.024” - 0.031”
Run Time @
50% Load
9 Hours with full tank
Engine Type
7 HP Four-stroke Overhead
Valve Design
Ignition
Recoil Start with Electronic
Ignition
Electrical Outlets
One 20A duplex NEMA
120V~receptacle
One 25A NEMA 120V 3 prong
twist lock receptacle
One T-Type 12V outlet
(10A DC Breaker)
Note: Additional specications found
in the TECHNICAL ENGINE
SPECIFICATIONS chart in this
manual.
The emission control system for this
engine is warranted for standards set by
the U.S. Environmental Protection Agency
and by the California Air Resources Board
(also known as CARB). For warranty
information, refer to the last pages of this
manual.
At high altitudes, the engine’s
carburetor, governor (if so equipped), and
any other parts that control the fuel-air
ratio will need to be adjusted by a qualied
technician to allow efcient high-altitude
use and to prevent damage to the engine
and any other devices used with this
product.
Functions
This unit can power items such as the
following:
ITEM RUNNING
WATTS
START-UP
WATTS
Belt Sander 1200 2400
Refrigerator/Freezer 700 2200
1/2 HP Sump Pump 1050 2150
1/2 HP Well Pump 1000 2100
Miter Saw 1650 3000
1-1/2 HP Capacitor Start
& Run Motor
1400 3100
Note: The above wattages are estimates.
Check nameplate wattages on all
loads before connecting to generator.
UNPACKING
When unpacking, check to make sure
that the item is intact and undamaged. If
any parts are missing or broken, please
call Harbor Freight Tools at
1-800-444-3353 as soon as possible.
REMOVE THESE BOLTS AND BRACKETS BEFORE USE!
There are two metal brackets
that hold the generator in place during
shipment to prevent damage. They must
be removed before use. See the photo
above.