Chicago Electric 67561 Portable Generator User Manual


 
Page 15For technical questions, please call 1-800-444-3353.SKU 67561
The air cleaner cover is held in place 2.
by clamps. Remove the clamps and
the cover.
Remove the air lter element.3.
Cleaning:4.
There are two foam lter elements. a.
Wash them in warm water and mild
liquid soap several times. Rinse.
Squeeze out excess water and allow
it to dry completely.
Soak the lter in lightweight oil b.
briey, then squeeze out the excess
oil.
Install the new lter or the cleaned 5.
lter. Secure the Air Cleaner Cover
before use.
Spark Plug Maintenance
Disconnect spark plug wire from 1.
end of plug. Clean out debris from
around spark plug.
Using a spark plug wrench, remove 2.
the spark plug.
Inspect the spark plug: 3.
If the electrode is oily, clean it using a
clean, dry rag.
If the electrode has deposits on it,
polish it using emery paper.
If the white insulator is cracked or
chipped, the spark plug needs to be
replaced.
When installing a new spark 4.
plug, adjust the plug’s gap to the
specication on the Technical
specication chart. Do not pry
against the electrode or the insulator,
the spark plug can be damaged.
Install the new spark plug or the 5.
cleaned spark plug into the engine.
Gasket-style: Finger-tighten until the
gasket contacts the cylinder head,
then about 1/2-2/3 turn more.
Non-gasket-style: Finger-tighten until
the plug contacts the head, then
about 1/16 turn more.
Apply dielectric spark plug boot 6.
protector (sold separately) to the end
of the spark plug and reattach the
wire securely.