Table 1-3 Auto Restart Sequencing (Continued)
Series
Attempt
Number
Intake
Heater
Energized
in
Seconds
Fuel
Solenoid
Engaged
Engine
Crank
Duration
(Seconds)
Engine
Rest
Duration
(Seconds)
Engine Status
4 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will de--energize.
b. Fuel solenoid will de--energize.
c. Crank output will de--energize.
d. Overcrank LED will flash four times. Wait
two seconds and repeat.
e. Unit will rest five hours and proceed to
the next series.
5 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will de--energize.
b. Fuel solenoid will de--energize.
c. Crank output will de--energize.
d. Overcrank LED will flash five times. Wait
two seconds and repeat.
e. Unit will rest five hours and proceed to
the next series.
6 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will de--energize.
b. Fuel solenoid will de--energize.
c. Crank output will de--energize.
d. Overcrank LED will illuminate solid and
lock out future crank attempts.
e. To reset, turn unit power switch OFF and
back ON.