Heater does not operate.
Element heats, fan does not
operate.
Fan operates, but does not dis-
charge warm air.
Heater does not shut off.
Heater discharges smoke.
Fan blades do not turn.
Manual reset limit trips
repeatedly.
1. Voltage not correct for application.
2. In line thermostat used.
3. Heater is or has been blocked.
4. Thermostat set too low.
5. Circuit breaker is off.
6. Defective manual reset.
1. Defective time delay switch.
2. Bad motor or wire connection.
3. Fan hitting or rubbing.
1. Manual reset limit tripped.
2. Defective heater elements.
3. Wire loose from elements.
1. Heat loss from area is greater than
heater capacity.
2. Defective thermostat.
1. Dust, dirt and lint accumulated
inside the heater.
2. Jammed fan blades.
1. Manual reset limit tripped.
2. Jammed fan blades.
3. Defective motor.
1. Overheating.
2. Overheating at shutdown.
3. Overheating from excessive dust,
dirt or lint particles.
4. Overheating due to location eleva-
tion.
5. Power interruptions.
1. Check voltage with voltmeter and/or consult an electrician.
2. Thermostat wires to terminal board; supply wires to junction block (see
wiring diagram).
3. Remove obstruction. Push manual reset in front.
4. Turn knob past sound of click.
5. Turn circuit breaker on.
6. Replace manual reset.
1. Replace the delay switch.
2. Replace motor and/or check wire connection.
3. Adjust blade as needed.
1. Allow heater to cool, then push reset button.
2. Check with ohmmeter and replace if needed.
3. Check and correct loose wire.
1. Close doors or windows. (See “Operation & Maintenance” section for
instructions).
2. Replace thermostat.
1. Clean heater. (See “Operation & Maintenance” section for instruction).
2. Remove obstruction.
1. Remove obstruction. Once heater has cooled, push reset button.
2. Remove obstruction.
3. Replace fan motor.
1. Check all clearance requirements.
2. Discontinue use of breaker to control heater, or replace time delay switch.
3. Clean heater. (See "Operation and Maintenance" section for instructions)
4. Location elevation exceeds recommended 7500 feet.
5. Power to heater needs to be constant.
Symptom Problem Solution
Troubleshooting Chart
Warranty Information
Maintenance: For safer operation and to prolong the life of the heater, it is necessary to follow the maintenance instructions included with each
heater. Failure to properly maintain the heater will result in the warranty being voided. All warranties offered to original consumer only. Warranty
instructions included with each heater.
All Cadet Products
LIMITED ONE-YEAR WARRANTY: LIMITED ONE-YEAR WARRANTY: Cadet Manufacturing Co. will repair or replace any Cadet product, including ther-
mostats, found to be defective or malfunctioning from first date of purchase through the first year.
Extended Product Warranties
Model CEH
LIMITED FIVE-YEAR WARRANTY: Cadet Manufacturing Co. will repair or replace any Cadet Unit Heater (CEH) element or motor found to be defective
or malfunctioning from first date of purchase through the fifth year.
THESE WARRANTIES DO NOT APPLY:
1. To conditions resulting from improper installation or incorrect supply voltage;
2. To conditions resulting from improper maintenance, misuse, abuse, accident, or alteration;
3. To service calls, or any warranty labor not performed at the Cadet Manufacturing facility;
4. If the date of manufacture cannot be determined;
5. To freight damaged products.
CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE AND/OR INCIDENTAL EXPENSES RESULTING FROM BREACH OF THESE
WRITTEN WARRANTIES OR ANY IMPLIED WARRANTY.
These warranties give you specific legal rights, and you may also have other rights which vary from state to state. Cadet neither assumes, nor
authorizes anyone to assume for it, any other obligation or liability in connection with these electric heaters or any part of such heaters.
If the product should become defective during the warranty period, contact Cadet Manufacturing Co. at 360-693-2505 for instructions on how to have
the repair or replacement processed. Products returned without authorization will be refused.
Parts and Service
Contact Cadet for information on parts or service.
©2006 Cadet Manufacturing Co. Printed in U.S.A. Rev. 11/06 #720019