Features
Switches 3 - 120V AC Sources
Compact solution when circuit protection is provided elsewhere
Allows connecting one of three different AC sources to one circuit
Heavy duty industrial rated switches
Intuitive function - One handed operation
UL listed switches
Specications
Amperage Rating: 32 Amperes Maximum
Voltage Rating: 600 Volts AC Maximum
Maximum Wire Size: 10 AWG
Minimum Wire Size: 14 AWG
Terminal Recommended Torque: 12 lb-in.
Inches Millimeters
Overall Dimensions: 1.890 x 1.890 48.00 x 48.00
Mounting Depth: 2.41 61.2
Maximum Panel Thickness: 0.157 4.00
BlueSeaSystemsInc. Phone(360)738-8230
425SequoiaDrive Fax(360)734-4195
Bellingham,WA98226USA www.bluesea.com
6684 Rev 002
WARNING
] These instructions are intended to provide assistance with the
installation of this product, and are not a substitute for a more
comprehensive understanding of electrical systems. We strongly
recommend that a competent electrical professional perform the
installation of this product.
] If either the switch front or back is to be exposed to water it must be
protected with a waterproof shield.
] The switch must not be installed in explosive environments such as
gasoline engine rooms or battery compartments as the switches
are not ignition proof.
] The vessel’s shore power cord must be disconnected form shoreside
power before installing this electrical switch.
] If an inverter is installed on the vessel its power leads must be
disconnected at the battery before the panel installation. Be aware that
many inverters have a “sleep mode” in which their voltage potential
may not be detectable with measuring equipment.
] If an AC Generator is installed aboard it must be stopped and rendered
inoperable before the switch is installed.
] Verify that no other AC or DC source is connected to the vessel’s
wiring before the switch is installed.
Guarantee:
Blue Sea Systems stands behind its products for as long as you own
them. Find detailed information at www.bluesea.com/about.
For customer service, call 800-222-7617.
Installation
1. DisconnectallACandDCpower
Disconnect all AC power originating on or off the vessel. This includes
inverters, generators, shore power attachments and any other device
capable of supplying AC power to the ship’s circuits.
Disconnect the main positive DC cable from all batteries to eliminate
the possibility of a short circuit and to disable the inverter while
installing the switch.
2. Selectmountinglocationandcutopening
Select a mounting location which is protected from water on the front
and back of the switch and is not in an area where ammable vapors
from propane, gasoline or lead acid batteries accumulate. AC rotary
switches are not ignition protected and may ignite such vapors.
Using the template provided, drill the mounting surface where the
switch is to be mounted. The mounting surface maximum thickness is
0.157” (4.00mm). Do not yet fasten the switch to the mounting surface.
3. Installsource1,source2,source3,andoutputwires
Install the feed wires from AC Shore Power and AC Generator. Install
the output wires. Refer to the wire sizing chart to select the proper wire
size. Connect the black AC hot, white AC neutral and green AC safety
ground as shown in the illustration. To avoid excess wire temperatures
when cooling may be limited, we recommend using at least 12 gauge
wire for 30A.
Do not confuse the neutral current carrying wires (sometimes called
ground) with the green normally non-current carrying wires (sometimes
called grounding). These two wires must be connected only at the
source of power, nowhere else.
A double pole circuit breaker must be installed within 10 feet of the
shore power inlet, ahead of this switch. The measurement is made
along the conductors.
AC Rotary Switch
3 Positions + OFF, 2 Pole
The switch provides switching, but does not provide circuit protection.
It is not a substitute for a main circuit breaker.
Wiresizingchart
Use the wire sizing chart below to determine the proper branch and
feed circuit wire sizes.
AllowableAmperageofConductors
4. Testing
It is very important that wiring be connected according to the diagram.
The hot lines and neutral from each source must be identied and
grouped together so that the switch selects all of the lines from the
same source and does not accidentally select lines or neutrals from
more than one source. Verify the connections and see that each
connection is securely tightened, including the terminals for the
jumpers installed on the switch where no wires are attached.
If you are using this switch for other purposes, such as voltage tap
selection on a transformer, please review your installation diagram and
devise a suitable test plan to verify your connections.
Page 1 of 3
Note:Thischartassumeswirewith105°Cinsulationrating
andnomorethan2conductorsarebundled.
Notsuitableforsizingexibleshorepowercords.