American Standard 2004 Multi-tool User Manual


 
SAVE FOR FUTURE USE
730865-100 Rev. M
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2011
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
!
NOTE: Pictures may not exactly define contour of china and components.
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read
these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
INSTALLATION INSTRUCTIONS
Champion
®
4
Model 2004 Normal Height Elongated One Piece Toilet
Model 2034 Right Height
®
Elongated One Piece Toilet
RECOMMENDED TOOLS AND MATERIALS
Putty Knife
Closet Bolts
Regular Screwdriver
Wax Ring/Gasket
Adjustable Wrench
Flexible Supply Tube
Sealant
Hacksaw
Carpenters Level
Tape Measure
2
CLOSET
FLANGE
CLOSET
BOLTS
A
ROUGHING-IN DIMENSIONS:
NOTE: Distance from wall to closet flange centerline must be as listed below:
INSTALL WAX SEAL
Invert toilet on floor (cushion to prevent
damage), and install wax ring evenly
around waste flange (horn), with tapered
end of ring facing toilet. Apply a thin
bead of sealant around toilet base.
POSITION TOILET ON FLANGE
a. Unplug floor waste opening and install toilet on closet
flange so bolts project through mounting holes.
b. Loosely install retainer washers and nuts. Side of
washers marked "THIS SIDE UP" must face up!
4 53
WAX RING
SEALANT
Model 2004
29-3/4
(756mm)
8
(203mm)
1-3/4 (44mm)
1-1/4
(32mm)
15
(381mm)
13-1/2
(343mm)
10-3/4
(273mm)
28-1/8
(714mm)
16-3/4
(425mm)
17-3/4
(451mm)
FINISHED WALL
18-1/2
(470mm)
C/L OF SEAT
POST HOLES
5-1/2 (140mm)
CENTERS
12
(305mm)
1/2
(13mm)
10-3/4
(273mm)
4-1/2
(114mm)
SUPPLY
AS
REQ'D
*
FINISHED
FLOOR
7
(178mm)
4
(102mm)
CLOSET
BOLT
NUT
TAPERED
WASHER
FLANGE
Recommended fitting type for back-to-back installations.
Depending upon your plumbing and venting conditions, the flow from
the Champion in a back-to-back installation may create a vacuum on
the system and draw water from the opposing bowl. The National
Standards Plumbing Code prohibits the use of a cross fitting for
drainage as throw over is possible. The code does approve a
directional "Y" style fitting with proper venting to direct the water
downward and away from the other toilet.
NOTE: BACK-TO-BACK INSTALLATION
REMOVE OLD TOILET
a. Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!
c. Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
NOTE: Mounting surface must be clean and level before new toilet is installed!
1
Model 2034
29-3/4
(756mm)
8
(203mm)
1-3/4 (44mm)
1-1/4
(32mm)
16-1/2
(419mm)
13-1/2
(343mm)
10-3/4
(273mm)
29-1/2
(749mm)
16-3/4
(425mm)
17-3/4
(451mm)
FINISHED WALL
1
(25mm)
1
(25mm)
18-1/2
(470mm)
C/L OF SEAT
POST HOLES
5-1/2 (140mm)
CENTERS
12
(305mm)
C/L OF OUTLETC/L OF OUTLET
1/2
(13mm)
10-3/4
(273mm)
4-1/2
(114mm)
SUPPLY
AS
REQ'D
*
FINISHED
FLOOR
7
(178mm)
3-3/4
(95mm)
INSTALL CLOSET BOLTS
Install closet bolts in flange
channel, turn 90°, and slide into
place 6" (152mm) apart and